Home / Microfluidic application notes / Setup: Microfluidic flow control
Microfluidic application notes

Category:
Setup: microfluidic flow control

We made a bold choice to fit both our mission, which is to boost science using microfluidics, as well as our culture, which is to do things our way and to be part of the research community.

We decided to promote and sell our instruments, not through common, boring advertisement, but instead by providing you with:

And then we hope that while surfing our website, some of you will discover our microfluidic brand and fall in love with Elveflow.

  • note

    Real-Time Fluorescence Analysis of Mixing in a Tesla Micromixer

    Real-Time Fluorescence Analysis of Mixing in a Tesla Micromixer

  • note

    Mechanoactivation of Single Stem Cells in Microgels Using a 3D-Printed Stimulation Device

    A microfluidic and pressure-driven platform enabling reproducible mechanoactivation of individually encapsulated stem cells under live-cell imaging in a true 3D environment.

  • note

    High-Resolution Microfluidic Device for Precise Oil-in-Water Emulsion and Coalescence Analysis

    Discover a high-resolution microfluidic device designed for precise oil-in-water emulsion studies and coalescence analysis. Learn how Elveflow's advanced flow control enhances petroleum research and beyond.

  • note

    Water-In-Oil Droplet Generation under Microscopy Monitoring

    Discover a simple and intuitive microfluidic water-in-oil droplet protocol under microscope monitoring

  • note

    Direct-Ink-Writing Flow Control with Elveflow Pressure Sensor

    This application note demonstrates a smart use ouf Elveflow's Pressure sensor and sensor reader for Direct-Ink-Writing flow control.

  • note

    Elveflow SDK Tutorial Part 1: Setting Up Your Environment on the OB1

    Learn how to set up your development environment for Elveflow products with this comprehensive tutorial.

  • note

    Utilizing a high precision microfluidic dead-end filtration setup to achieve global alignment of single walled carbon nanotubes

    Single-wall carbon nanotubes (SWCNTs) are considered as quasi 1-dimensional (1D) carbon nanostructures, which are known for their outstanding anisotropic electronic, mechanical, thermal and optical properties.

  • note

    How do you synchronize a microscope with a microfluidic perfusion system?

    This application note describes how to combine and synchronise liquid perfusion and imaging using an Olympus spinning disc confocal microscope together with an Elveflow pressure-driven flow controlled microfluidic system.

  • note

    REDIRECTING FLOW WITH A MICROFLUIDIC VALVE CONTROLLER

    The MUX Wire enables you to host up & control many valves of your choice. It gives you a total freedom to add up to 16 valves and put them anywhere in your set-up and control them independently and simultaneously.

  • note

    Active Micromixers-on-a-Chip

    Mixing is a crucial step for several microfluidic applications like chemical synthesis, clinical diagnostics, sequencing and synthesis of nucleic acids

  • note

    Nanoparticle generator

    This application note describes how microfluidic can be employed as a nanoparticle generator based on the example of PLGA bead generation.

  • note

    Microfluidic colocalization set-up for DNA analysis

    This user guide will show you how to run microfluidic colocalization studies of single molecule spectroscopy.

  • note

    Exploring Pneumatic Pumps and Pressure-Driven Flow Control Technology

    This application note explores the basic principle of pneumatic pumps and a flow controller based on the basic principle of pneumatic pumps, known as pressure driven flow control. It also demonstrates the applications of pressure driven flow control in a range of industrial & research fields.

  • note

    Fluid handling

    Microfluidics is the science of handling small amounts of liquids, inside micrometer scale channels. Discover how to handle fluids for your microfluidic experiments.

  • note

    How to choose flow regulation parameters?

    Flow regulation is a compulsory operation in most of the microfluidics operations. In some applications such as 2D or 3D cell culture, flow regulation is essential since accurate micro-environmental parameters control is required. Elveflow do it’s best to make this operation as easy as possible to help you to focus on what really matter in your setup.

  • note

    Cross flow membrane for molecular transport

    Study the impact of molecular transport on cell cultures with a cross flow membrane chip and microfluidic instruments.

  • note

    Controlled liquid injection system in a continuous flow using MUX valves

    Precise liquid injection system for manipulation of small volumes of fluids using the MUX distribution and the MUX recirculation valve.

  • note

    Octanol-assisted liposome assembly (OLA) using Elveflow pumps

    This application note explains how to set up a robust and reproducible microfluidic platform for liposomes assembly with improved encapsulation efficiency and reduced polydispersity in size.

  • note

    Pressure sensor Feedback Loop

    This application note demonstrates how to manage pressure in microfluidic systems and monitor real-time pressure in your setup for precise control.

  • note

    Shear stress calculator

    The application note describes how to convert various units of shear stress and/or pressure from one to another: shear stress conversion from Pascal, atmosphere, and N/m²...!

  • note

    Preparation of PLGA nanoparticles by flow focusing

    Learn how to perform PLGA nanoparticle preparation with Elveflow instruments and a microfluidic chip

  • note

    viscosity conversion

    The application note describes how to convert various units of viscosity from one to another: viscosity conversion from Poise, Pa.s, Dyn.s/cm²...

  • note

    Microfluidic resistance calculator

    Elveflow's developped a microfluidic resistance calculator dependent upon the microfluidic system from the flow rate, the device, the tubing to your fluid properties.

  • note

    Calculate flow rate microfluidics

    Elveflow's microfluidic calculator permits to calculate flow rate in microfluidics dependent upon the microfluidic system from the device, the tubing to your fluid properties.

  • note

    Microfluidic calculator by Elveflow | Application note

    Elveflow developped a free online microfluidic calculator. This tool has been designed to help researchers and especially non specialists of the microfluidics field. It helps you assess key parameters to configure your microfluidic experiment. 

  • note

    Flow regulation with flow sensors and smart interface

    The aim of this application note is to show how to easily perform a very responsive and precise flow rate control anywhere in your setup by using an Elveflow® OB1 pressure & flow controller and a Bronkhorst® flow sensor.

  • note

    Peristaltic pump compared to pressure driven flow control

    In this review we will explain the operating principle of pressure driven flow control, the advantages / disadvantages of the different technologies and how to choose between a peristaltic pump and pressure control depending on your requirements.

  • note

    Avoid air bubbles during your microfluidic experiments

    Air bubbles are a very common issue for microfluidic experiments. They are very difficult to avoid, and they can be really difficult to remove from the microfluidic device. Moreover, they can be really detrimental for the experiment.

  • note

    How to use Elveflow Microfluidic Bubble detector

    Gas bubbles circulating through a microfluidic setup can damage the biological sample of interest and/or cause experimental errors

  • note

    Microfluidic soft-robots

    Soft-Robotics: Creation and Control of microfluidic soft-robots

  • note

    Fluorescence probe quantification

    The fluorescence probe is a robust and highly sensitive approach for detecting trace amounts of substance owing to its simplicity and non-invasiveness. Moreover, the use of optical methods, which is usually low cost, light-weight, high throughput and can be easily deployed in large scale for on-field or point-of-care applications.

  • note

    Fiber optic sensor

    The OptoReader is a highly sensitive detection device taking advantage of advanced photo-detection technologies. Its optical fiber based design and its capacity of both excitation and detection of fluorescence makes it the ideal device for working with fiber optic sensors.

  • note

    Controlled medium switch on a microfluidic chip

    Changing the injected liquid inside a microfluidic device has numerous applications, such as sequential sample injection for biochemistry and flow chemistry, or medium switch for cell biology and 3D cell culture on chip. The easiest solution is to replace the liquid injected, but it is often not possible:

  • note

    Microfluidic fast medium switch (OB1+MUX)

    This application note shows how to perform an ultrafast microfluidic medium switch (drugs, samples, etc) in an hypothetical chemical or biological environment, performed with an Elveflow® OB1 and an Elveflow® MUX

  • note

    Microfluidic fast medium switch (OB1)

    This application note shows how to perform an ultrafast microfluidic medium (drugs, samples, etc) change in an hypothetical chemical or biological environment, performed with an Elveflow® pressure & flow control instrument (OB1) as shown in these pictures:

  • note

    Microfluidic controlled drug switch

    This application note shows how to easily perform controlled drug switches on an hypothetic chemical or biological environment (drug screening or cell culture) with an Elveflow® MUX as shown on these pictures:

  • note

    OB1 pressure controller: How to install out of the box

    A series of videos produced specifically to provide our customers with the best experience.

  • note

    How to control the flow using an OB1 pressure controller and a flow sensor?

    Microfluidic flow control : The OB1® pressure controller has the advantage to be the faster and the most stable of the microfluidic flow controller. In combination with a flow sensor, it can also perform an ultra-precise flow control and monitor the amount of liquid injected in a chips. You can request a flow rate value in the Elveflow Software and the pressure controller will automatically adjust pressure to reach the requested value thanks to a customizable PID Feedback loop. This application note aims to guide you to easily perform this flow control.

  • note

    Pressure driven flow control for Nanofluidics

    Nanofluidics is the study of the behaviour, manipulation, and control of fluids that are confined to structures of nanometer characteristic dimensions. Various reasons may be found to motivate the development of Nanofluidics. From a biotechnological point of view, decreasing the scales considerably increases the sensitivity of analytic techniques. From a fluidic point of view, nanometric scales allow new fluidic functionalities to be developed, using the explicit benefit of the predominance of surfaces.

  • note

    Pressure-driven flow control

    This application note explains how pressure-driven flow control works, the advantages & disadvantages of the different technologies, and the technical choice to make to how to perform effectively your microfluidic experiment.

  • note

    Using an Elveflow controller as a syringe pump

    This application note describes how to set and monitor a determined liquid flow rate and perform a flow control for your microfluidic experiments by using an Elveflow® pressure & flow control instrument and a flow sensor. The new version of the Elveflow® smart software allows to virtually turn your pressure controller into a syringe pump keeping the advantages of both methods (high performance, ease of use, intuitiveness, etc.)

  • note

    Flow Chemistry and sample preparation

    The advent of microfluidics as a tool for chemical synthesis is coming of age, particularly in industrial techniques. It has many advantages over conventional techniques such as as small reagent consumption, improved selectivity, less stringent reaction clean up, rapid reactions and small footprints.

  • note

    Zero Flow microfluidic experiment

    This application note describes how to generate a controlled flow inside a microfluidic chip and stop it completely (zero flow) by using an Elveflow® pressure control instrument (OB1) and valves.

  • note

    Fluid recirculation – Perfusion microfluidic system

    The MUX Inj is a bidirectional 6-port / 2 position valve allowing to perform switches between two setup configurations. One application is to make a fluid recirculation set-up with a flow rate always going through the chip in the same direction. In this application note, we walk you through the steps of setting up a unidirectional recirculation through a semi permeable membrane.

  • note

    Microfluidic Flow Restrictors

    The flow rate in every fluidic system can be computed with the following equation: ∆P=Q×Rh Where: ∆P is the pressure difference between the inlet and the outlet of the system, Q is the flow rate throughout the system, Rh is the fluidic resistance of the system.

  • note

    Microfluidics flow focusing

    Hydrodynamic flow focusing is a powerful tool in the field of microfludics that can be used for numerous applications, such as microfluidic mixing, separations, sensors, cell analysis, flow cytometry, diffusion-controlled chemical reactions and microfabrication. Hydrodynamic focusing occurs when fluids with different velocities are injected side by side. The most common way to perform hydrodynamic focusing is to use a 3 inlets microfluidic chips, where the core flow containing the sample of interest is sheathed by an inert fluid.

  • note

    Rheodyne microfluidic valve bidirectional ten-way injection

    Maintain a controlled flow rate? This application note aims to help you maintain a controlled flow rate during a flow line switch thanks to the Mux Distributor. This valve allows to switch between up to 10 lines to inject several fluids sequentially in your system. It has many applications such as sequential sample injection for biochemistry and flow chemistry, or medium switch for cell biology on chip.

  • note

    Flow measurement with flow sensors and smart interface

    How to control the flow rate in your setup with very high accuracy thanks to flow measurement? The aim of this application note is to show how to easily perform a very responsive and precise flow rate control anywhere in your setup by using an Elveflow® OB1 pressure & flow controller and a Bronkhorst® flow sensor.

  • note

    Controlled microfluidic sample injection

    The MUX inj is a bidirectional 6-port / 2 position valve allowing to perform switches between two set-up configurations. One application is to perform a stable and unidirectional fluid recirculation or to inject a precisely controlled volume of drug. This application note focuses on the example and will walk you through the steps of a successful experiment.

  • note

    Instantaneous stop flow using flow multiplexer

    Because of fluidic compliance of tubing and chip, achieving stop flow into a microfluidic device remain a challenge with conventional setup. One solution to achieve stop flow in hundreds of milliseconds into a microchip without residual flow is to use a pressure controller coupled with flow switch.

Contact
How can we help you?
Quoteor technical request
Job application Job
application
Collaboration or partnerships Collaborations
or partnerships
Customer support Customer
support
Others questions Other

For more information or Technical discussion

Contacting for
a job application?
We are happy that you are interested in Elveflow. You can apply to our open jobs or send us your open application. Over here!

For more information or Technical discussion

Need customer support?

For more information or Technical discussion